Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 297
Filtrar
1.
Heliyon ; 10(6): e27758, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38524600

RESUMEN

Introduction: For experimental studies on sound transfer in the middle ear, it may be advantageous to perform the measurements without the inner ear. In this case, it is important to know the influence of inner ear impedance on the middle ear transfer function (METF). Previous studies provide contradictory results in this regard. With the current study, we investigate the influence of inner ear impedance in more detail and find possible reasons for deviations in the previous studies. Methods: 11 fresh frozen temporal bones were prepared in our study. The factors related to inner ear impedance, including round window membrane stiffness, cochleostomy, cochlea fluid and cochlea destruction were involved in the experimental design. After measuring in the intact specimen as a reference (step 1), the round window membrane was punctured (step 2), then completely removed (step 3). The cochleostomy was performed (step 4) before the cochlear fluid was carefully suctioned through scala tympani (step 5) and scala vestibuli (step 6). Finally, cochlea was destroyed by drilling (step 7). Translational and rotational movement of the stapes footplate were measured and calculated at each step. The results of the steps were compared to quantify the effect of inner ear impedance changing related to the process of cochlear drainage. Results: As the inner ear impedance decreases from step 1 to 7, the amplitudes of the METF curves at each frequency gradually increase in general. From step 6 on, the measured METF are significantly different with respect to the intact group at high frequencies above 3 kHz. The differences are frequency dependent. However, the significant decrement of rotational motion appears at the frequencies above 4.5 kHz from the step 5. Conclusion: This study confirms the influence of inner ear impedance on METF only at higher frequencies (≥3 kHz). The rotational motions are more sensitive to the drainage of fluid at the higher frequency. Study results that found no influence of cochlea impedance may be due to incomplete drainage of the cochlea.

2.
Front Pharmacol ; 15: 1384445, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38500770

RESUMEN

[This corrects the article DOI: 10.3389/fphar.2024.1348172.].

3.
Cureus ; 16(2): e54360, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38500948

RESUMEN

Different techniques have been proposed for cochlear implant (CI) from its conventional transmastoid posterior tympanotomy approach. Endoscopy role in the otologic field is still relatively new, but it provides a better surgical view with improved image clarity, especially in the challenging anatomical visualization of the critical structures in CI surgery. A 3-year-old girl with bilateral progressive profound hearing loss was scheduled for left cochlear implant surgery. The pre-operative high-resolution computed tomography (HRCT) of the temporal bone and magnetic resonance (MR) of internal acoustic meatus reported no significant abnormality of the middle and inner ears structures bilaterally. The standard left postauricular cortical mastoidectomy and posterior tympanotomy were performed. However, the microscopic view could not visualize the round window (RW) niche despite a widened extended posterior tympanotomy and surgical field manipulation. Transfacial recess endoscopic examination was done and was able to identify the possibly atretic RW. With endoscopic guidance, CI electrodes were inserted via cochleostomy, and intraoperative impedance measurement and neural response telemetry were obtained both during surgery and the postoperative phase. No intra- and postoperative complications were observed in this case. Following activation, the CI was functioning well. In conclusion, atretic RW is a rare anomaly found intraoperatively during CI surgery. Endoscope-assisted electrode insertion offers excellent visualization of targeted middle ear structures, especially in limited or abnormal anatomy of RW, which could minimize the risk of surgical complications.

4.
Am J Otolaryngol ; 45(3): 104231, 2024 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-38513514

RESUMEN

PURPOSE: Hyperacusis is an audiological disorder in which patients become persistently sensitive and intolerant to everyday environmental sounds. For those patients that fail conservative options, a minimally invasive surgical procedure has been developed. MATERIALS & METHODS: Retrospective case series of 73 adult patients with hyperacusis who underwent oval and round window reinforcement surgery between 1/2017-6/2023. Small pieces of temporalis fascia were used to reinforce the round and oval windows. Patients were separated into two groups based on their preoperative speech Loudness Discomfort Level (LDL). Patients with a preoperative speech LDL ≤ 70 dB were placed in the "low LDL group" whereas patients with a preoperative speech LDL >70 dB were placed in the "high LDL group." Preoperative and one-week postoperative audiogram and speech LDLs were compared. Quality of life was assessed using the Glasgow Benefit Inventory (GBI) survey. RESULTS: 73 patients met inclusion criteria - 21 patients in the low LDL group and 52 in the high LDL group. Patients in the high LDL group significantly improved their LDLs by an average of 3.5 dB (P < 0.0001). 42 patients (80.8 %) in the high LDL group had improvement and would recommend the surgery for hyperacusis. Patients in the low LDL group significantly improved their LDL by an average of 12.9 dB (P = 0.032). Ten patients (47.6 %) from the low LDL group experienced improvement and would recommend hyperacusis surgery. CONCLUSION: Many patients with hyperacusis who undergo oval and round window reinforcement can receive significant improvement in sound tolerance and quality of life. Patients with a pre-op speech LDL > 70 dB have the greatest potential for improvement with surgery (80.8 %), probably because their hyperacusis was less severe.

5.
Indian J Otolaryngol Head Neck Surg ; 76(1): 944-952, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38440460

RESUMEN

Aim: The aim was to study the radiological parameters using High Resolution Computed Tomography (HRCT) temporal bone to predict the Round Window Niche (RWN) visibility through the facial recess approach and to study radiological types of the round window niche. Materials and Methods: Prospective study was done in the patients underwent CI surgery from 2019 to 2021. HRCT radiological parameters of the patients and their intraoperative visualisation from video recordings were compared to predict the most feasible parameters to predict good visualisation of RWN. Results: Among 51 patients (34 males, 17 females) in 48 children round window membrane insertion was done and in three children cochleostomy was done and in two children partial canal wall drilling was done due to poor visualisation of RWN area. Multiple parameters to assess the visibility of the RWN were used. Facial recess width (4.2 mm), location of the mastoid segment of facial nerve (2 mm), external auditory canal to basal turn of cochlea angle (< 13.50) and the radiological types (tunnel shape and semi-circular shape) of the RWN by HRCT were found to be significant parameters in predicting a good visualisation of the RWN. Conclusion: HRCT parameters prepare the surgeon to face the possibility of a difficult surgery and plan to deal with difficult situations. This would eventually lead to better preparedness of surgeons for management of complications.

6.
Indian J Otolaryngol Head Neck Surg ; 76(1): 781-787, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38440579

RESUMEN

Purpose: The round window approach has become the most preferred route for electrode insertion in cochlear implant surgery; however, it is not possible at times due to difficult round window membrane (RWM) visibility. Our study aims to investigate the relationship between preoperative radiological parameters and the surgical visibility of the RWM in Cochlear implant patients. Methodology: A prospective cross-sectional study of 31 patients, age < 6 years, with bilateral severe to profound sensorineural hearing loss was conducted at a tertiary care hospital. The preoperative HRCT temporal bone scan was studied, and the parameters evaluated were facial nerve location, facial recess width, and RWM visibility prediction. All patients were operated on via the posterior tympanotomy. The surgical RWM visibility was done after optimal drilling of the posterior tympanotomy recess. The relationship between the radiological parameters and surgical visibility of RWM was evaluated. Results: The difference in the facial nerve location as per the type of RWM was found to be significant (p value < 0.05). However, the facial recess width was not significantly associated with RWM visibility. The radiological prediction of RWM visibility by tracing the prediction line over RWM was significantly associated with intraoperative RWM visibility. Conclusion: The goal to look for preoperative scans is to predict the ease or difficulty of RWM visibility during surgery. The difficult visualization of the RWM, can result in dire intraoperative consequences. A comprehensive understanding of preoperative radiological parameters, coupled with meticulous surgical planning, is crucial to address these challenges effectively by focusing on enhancing RWM visualization.

7.
Front Pharmacol ; 15: 1348172, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38344174

RESUMEN

Introduction: One major obstacle in validating drugs for the treatment or prevention of hearing loss is the limited data available on the distribution and concentration of drugs in the human inner ear. Although small animal models offer some insights into inner ear pharmacokinetics, their smaller organ size and different barrier (round window membrane) permeabilities compared to humans can complicate study interpretation. Therefore, developing a reliable large animal model for inner ear drug delivery is crucial. The inner and middle ear anatomy of domestic pigs closely resembles that of humans, making them promising candidates for studying inner ear pharmacokinetics. However, unlike humans, the anatomical orientation and tortuosity of the porcine external ear canal frustrates local drug delivery to the inner ear. Methods: In this study, we developed a surgical technique to access the tympanic membrane of pigs. To assess hearing pre- and post-surgery, auditory brainstem responses to click and pure tones were measured. Additionally, we performed 3D segmentation of the porcine inner ear images and used this data to simulate the diffusion of dexamethasone within the inner ear through fluid simulation software (FluidSim). Results: We have successfully delivered dexamethasone and dexamethasone sodium phosphate to the porcine inner ear via the intratympanic injection. The recorded auditory brainstem measurements revealed no adverse effects on hearing thresholds attributable to the surgery. We have also simulated the diffusion rates for dexamethasone and dexamethasone sodium phosphate into the porcine inner ear and confirmed the accuracy of the simulations using in-vivo data. Discussion: We have developed and characterized a method for conducting pharmacokinetic studies of the inner ear using pigs. This animal model closely mirrors the size of the human cochlea and the thickness of its barriers. The diffusion time and drug concentrations we reported align closely with the limited data available from human studies. Therefore, we have demonstrated the potential of using pigs as a large animal model for studying inner ear pharmacokinetics.

8.
Int Arch Otorhinolaryngol ; 28(1): e107-e114, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38322445

RESUMEN

Introduction Cochlear implantation has been considered as the best treatment in patients with severe to profound hearing loss unaidable with hearing aids. The main value of endoscope-assisted cochlear implantation is improved visibility of the RW Objective to assess the value of endoscopic assisted CI surgery via facial recess approach without elevating tympanic anulus. Methods This Prospective case series study non-randomized sample was performed on 50 patients with severe to profound hearing loss unaidable with hearing aids undergoing unilateral endoscopic assisted cochlear implant surgery with round window electrode insertion Results There were 23 male and 27 female patients. Most of the cases were children (41 cases). Of those 50 patients, 39 were prelingually hearing impaired. Four cases had various inner ear abnormalities. The standard mastoidectomy and Posterior Tympanotomy approach were used for all cases. Endoscopic identification of the RW through the PT enabled us to perform regular surgery in all cases. The current study concludes the difference between microscopic exposure and endoscopic exposure represented by Saint Tomas classification found that endoscopic exposure of round window classification is better represented by downgrading in the classification of round window exposure as type I 29(58%), type IIa 18(36%) type IIb 3 (6%) Non were type III by endoscopic exposure compared to microscopic exposure of round window is a type I 7(14%), type II 14(28%), type IIb 22(44%) and type III 7 (14%). Conclusion Endoscopy proved a great value in exposure and identification of RW in CI surgery through posterior tympanotomy approach.

9.
Laryngoscope ; 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38379206

RESUMEN

INTRODUCTION: The round window membrane (RWM) presents a significant barrier to the local application of therapeutics to the inner ear. We demonstrate a benchtop preclinical RWM model and evaluate superparamagnetic iron oxide nanoparticles (SPIONs) as vehicles for magnetically assisted drug delivery. METHODS: Guinea pig RWM explants were inset into a 3D-printed dual chamber benchtop device. Custom-synthesized 7-nm iron core nanoparticles were modified with different polyethylene glycol chains to yield two sizes of SPIONs (NP-PEG600 and NP-PEG3000) and applied to the benchtop model with and without a magnetic field. Histologic analysis of the RWM was performed using transmission electron microscopy (TEM) and confocal microscopy. RESULTS: Over a 4-h period, 19.5 ± 1.9% of NP-PEG3000 and 14.6 ± 1.9% of NP-PEG600 were transported across the guinea pig RWM. The overall transport increased by 1.45× to 28.4 ± 5.8% and 21.0 ± 2.0%, respectively, when a magnetic field was applied. Paraformaldehyde fixation of the RWM decreased transport significantly (NP-PEG3000: 7.6 ± 1.5%; NP-PEG600: 7.0 ± 1.6%). Confocal and electron microscopy analysis demonstrated nanoparticle localization throughout all cellular layers and layer-specific transport characteristics within RWM. CONCLUSION: The guinea pig RWM explant benchtop model allows for targeted and practical investigations of transmembrane transport in the development of nanoparticle drug delivery vehicles. The presence of a magnetic field increases SPION delivery by 45%-50% in a nanoparticle size- and cellular layer-dependent manner. LEVEL OF EVIDENCE: NA Laryngoscope, 2024.

10.
Laryngoscope ; 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38197496

RESUMEN

OBJECTIVE(S): Recently directed methods of inner ear drug delivery underscore the necessity for understanding critical anatomical dimensions. This study examines anatomical measurements of the human middle and inner ear relevant for inner ear drug delivery studied with three different imaging modalities. METHODS: Post-mortem human temporal bones were analyzed using human temporal bone histopathology (N = 24), micro computerized tomography (µCT; N = 4), and synchrotron radiation phase-contrast imaging (SR-PCI; N = 7). Nine measurements involving the oval and round windows were performed when relevant anatomical structures were visualized for subsequent age-controlled analysis, and comparisons were made between imaging methods. RESULTS: Combined human temporal bone histopathology showed the mean distance to the saccule from the center of the stapes footplate (FP) was 2.07 ± 0.357 mm and the minimum distance was 1.23 mm. The mean distance from the round window membrane (RWM) to the osseous spiral lamina (OSL) was 1.75 ± 0.199 mm and the minimum distance was 1.43 mm. Instruments inserted up to 1 mm past the center of the FP are unlikely to cause saccular damage, provided there are no endolymphatic hydrops. Similarly, instruments inserted up to 1 mm through the RWM in the trajectory toward the OSL are unlikely to cause OSL damage. CONCLUSION: The combined analyses of inner-ear dimensions of age-controlled groups and imaging modalities demonstrate critical dimensions of importance to consider when inserting delivery vehicles into the human cochlea. LEVEL OF EVIDENCE: N/A Laryngoscope, 2024.

11.
Hear Res ; 442: 108950, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38218017

RESUMEN

Countless therapeutic antibodies are currently available for the treatment of a broad range of diseases. Some target molecules of therapeutic antibodies are involved in the pathogenesis of sensorineural hearing loss (SNHL), suggesting that SNHL may be a novel target for monoclonal antibody (mAb) therapy. When considering mAb therapy for SNHL, understanding of the pharmacokinetics of mAbs after local application into the middle ear is crucial. To reveal the fundamental characteristics of mAb pharmacokinetics following local application into the middle ear of guinea pigs, we performed pharmacokinetic analyses of mouse monoclonal antibodies to FLAG-tag (FLAG-mAbs), which have no specific binding sites in the middle and inner ear. FLAG-mAbs were rapidly transferred from the middle ear to the cochlear fluid, indicating high permeability of the round window membrane to mAbs. FLAG-mAbs were eliminated from the cochlear fluid 3 h after application, similar to small molecules. Whole-body autoradiography and quantitative assessments of cerebrospinal fluid and serum demonstrated that the biodistribution of FLAG-mAbs was limited to the middle and inner ear. Altogether, the pharmacokinetics of mAbs are similar to those of small molecules when locally applied into the middle ear, suggesting the necessity of drug delivery systems for appropriate mAb delivery to the cochlear fluid after local application into the middle ear.


Asunto(s)
Oído Interno , Pérdida Auditiva Sensorineural , Ratones , Cobayas , Animales , Anticuerpos Monoclonales/metabolismo , Distribución Tisular , Oído Interno/metabolismo , Cóclea/metabolismo , Oído Medio , Ventana Redonda/metabolismo , Pérdida Auditiva Sensorineural/metabolismo
12.
Audiol Res ; 14(1): 62-76, 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38247562

RESUMEN

Background: Since the discovery of the perilymphatic fistula (PLF), the diagnosis and treatment remain controversial. If successfully recognized, the PLF is surgically repairable with an obliteration of the fistula site. Successful treatment has a major impact on patient's quality of life with an improvement in their audiological and vestibular symptoms. Objective: To prospectively investigate patients' clinical and audiological evolution with PLF suspicion after middle ear exploration and obliteration of the round and oval window. Study Design: Prospective comparative study. Setting: Tertiary care center. Methods: Patients were divided into two groups: Group I consisted of patients where no PLF had been identified intraoperatively at the oval and/or at the round window, and Group II consisted of patients where a fistula had been visualized. Patient assessment was a combination of past medical history, the presence of any risk factors, cochlear and vestibular symptoms, a physical examination, temporal bone imaging, audiograms, and a videonystagmogram (VNG). Results: A total of 98 patients were divided into two groups: 62 in Group I and 36 in Group II. A statistically significant difference regarding gender was observed in Group II (83.3% of males vs. 16.7% of females, p = 0.008). A total of 14 cases (4 and 10 in Groups I and II, respectively) were operated for a recurrent PLF. Fat graft material was used in the majority of their previous surgery; however, no difference was found when comparing fat to other materials. In addition, no statistically significant difference was noted between Groups I and II concerning predisposing factors, imaging, VNG, symptom evolution, or a physical exam before the surgery and at 12 months post-operative. However, both groups showed statistically significant hearing and vestibular improvement. On the other hand, the air conduction (AC) and bone conduction (BC) at each frequency were not statistically different between the two groups before surgery but showed statistically significant improvement at 12 months post-operatively, especially for the BC at the frequencies 250 (p = 0.02), 500 (p = 0.0008), and 1000 Hz (p = 0.04). Conclusions: Whenever you suspect a perilymphatic fistula, do not hesitate to explore middle ear and do window obliterations using a tragal perichondrium material. Our data showed that cochlear and vestibular symptoms improved whether a fistula had been identified or not.

13.
Artículo en Inglés | MEDLINE | ID: mdl-38294508

RESUMEN

INTRODUCTION: Round window approach and cochleostomy approach can have different depth of electrode insertion during cochlear implantation which itself can alter the audiological outcomes in cochlear implant. OBJECTIVE: The current study was conducted to determine the difference in the depth of electrode insertion via cochleostomy and round widow approach when done serially in same temporal bone. METHODOLOGY: This is a cross-sectional study conducted in the Department of Otorhinolaryngology in conjunction with Department of Anatomy and Department of Diagnostic and Interventional Radiology over a period of 1 year. 12-electrode array insertion was performed via either approach (cochleostomy or round window) in the cadaveric temporal bone. HRCT temporal bone scan of the implanted temporal bone was done and depth of insertion and various cochlear parameters were calculated. RESULT: A total of 12 temporal bones were included for imaging analysis. The mean cochlear duct length was 32.892 mm; the alpha and beta angles were 58.175° and 8.350°, respectively. The mean angular depth of electrode insertion via round window was found to be 325.2° (SD = 150.5842) and via cochleostomy 327.350 (SD = 112.79) degree and the mean linear depth of electrode insertion via round window was found to be 18.80 (SD = 4.4962) mm via cochleostomy 19.650 (SD = 3.8087) mm, which was calculated using OTOPLAN 1.5.0 software. There was a statically significant difference in linear depth of insertion between round window and cochleostomy. Although the angular depth of insertion was higher in CS group, there was no statistically significant difference with round window type of insertion. CONCLUSION: The depth of electrode insertion is one of the parameters that influences the hearing outcome. Linear depth of electrode insertion was found to be more in case of cochleostomy compared to round window approach (p = 0.075) and difference in case of angular depth of electrode insertion existed but not significant (p = 0.529).

14.
Laryngoscope ; 134(1): 388-392, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37318112

RESUMEN

OBJECTIVES: Oral or intratympanic corticosteroids are commonly used to treat sudden sensorineural hearing loss (SSHL), tinnitus, and Meniere disease. Direct intracochlear delivery has been proposed to overcome the variability in bioavailability and efficacy of systemic or middle ear delivery. In this study, we aim to characterize the physiologic consequences of microneedle-mediated direct intracochlear injection of dexamethasone through the round window membrane (RWM). METHODS: In Hartley guinea pigs (n = 5), a post-auricular incision followed by bullostomy was made to access the round window membrane. Using 100 µm diameter hollow microneedles, 1.0 µl of 10 mg/ml dexamethasone was injected through the RWM over 1 min. Compound action potential (CAP) and distortion product otoacoustic action emissions (DPOAE) were measured before perforation, at 1 h, and at 5 h following injection. CAP hearing thresholds were measured from 0.5 to 40 kHz, and DPOAE f2 frequencies ranged from 1.0 and 32 kHz. Repeated measures ANOVA followed by pairwise t-tests were used for statistical analysis. RESULTS: ANOVA identified significant CAP threshold shifts at four frequencies (4, 16, 36, and 40 kHz) and differences in DPOAE at 1 frequency (6 kHz). Paired t-tests revealed differences between the pre-perforation and 1 h time point. By 5 h post injection, both CAP hearing thresholds and DPOAE recover and are not significantly different from baseline thresholds. CONCLUSION: Direct intracochlear delivery of dexamethasone via microneedles results in temporary shifts in hearing thresholds that resolve by 5 hours, thus supporting microneedle technology for the treatment of inner ear disorders. LEVEL OF EVIDENCE: NA Laryngoscope, 134:388-392, 2024.


Asunto(s)
Pérdida Auditiva Sensorineural , Enfermedad de Meniere , Acúfeno , Cobayas , Animales , Audición , Dexametasona
15.
Adv Drug Deliv Rev ; 204: 115145, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38042259

RESUMEN

Treating pathologies of the inner ear is a major challenge. To date, a wide range of procedures exists for administering therapeutic agents to the inner ear, with varying degrees of success. The key is to deliver therapeutics in a way that is minimally invasive, effective, long-lasting, and without adverse effects on vestibular and cochlear function. Microbubble-assisted ultrasound ("sonoporation") is a promising new modality that can be adapted to the inner ear. Combining ultrasound technology with microbubbles in the middle ear can increase the permeability of the round window, enabling therapeutic agents to be delivered safely and effectively to the inner ear in a targeted manner. As such, sonoporation is a promising new approach to treat hearing loss and vertigo. This review summarizes all studies on the delivery of therapeutic molecules to the inner ear using sonoporation.


Asunto(s)
Oído Interno , Microburbujas , Humanos , Sistemas de Liberación de Medicamentos , Ultrasonografía
16.
Laryngoscope ; 134(3): 1396-1402, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37638702

RESUMEN

OBJECTIVES: To determine the morphologies and effect of the round window niche veil (RWNV) on local drug delivery efficacy and develop diagnostic criteria on high-resolution computed tomography (HRCT). METHODS: Patients diagnosed with otosclerosis, bilateral profound sensorineural hearing loss or vestibular schwannoma were enrolled from 2019 to 2022, receiving temporal bone HRCT scanning, and anatomic variations of RWMV were summarized intraoperative. For patients with vestibular schwannoma, 1 mL of dexamethasone solution (4 mg/mL) was administered via facial recess during operation, and samples of perilymph were collected to analyze. The diagnostic criteria of RWNV on HRCT were developed and verified. RESULTS: A total of 85 patients were enrolled. RWNV was observed in 54 cases intraoperatively with an incidence of 63.5% (95% CI, 52.9%-73.0%). The median perilymph concentrations were 4.86-fold higher in the group without RWNV than with RWNV (p < 0.0001). RWNV could be visualized on HRCT with a window width of 3500-4500 HU and a window level of 300-500 HU. The characteristic features were as follows: (1) a thin soft tissue shadow could be seen at the entrance of the round window niche (RWN); (2) it was visible in at least 2 consecutive layers along the upper margin of RWN from top to bottom; (3) it was discontinuous with the adjacent bone margin. The sensitivity and specificity of the diagnostic criteria were 77.8% and 93.6%, respectively. CONCLUSION: RWNV could reduce local dexamethasone diffusion efficacy to the inner ear, which could be diagnosed on HRCT and used as a predictor of local drug delivery efficacy to the inner ear. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:1396-1402, 2024.


Asunto(s)
Oído Interno , Pérdida Auditiva Sensorineural , Neuroma Acústico , Humanos , Ventana Redonda/diagnóstico por imagen , Ventana Redonda/cirugía , Oído Interno/diagnóstico por imagen , Pérdida Auditiva Sensorineural/diagnóstico por imagen , Pérdida Auditiva Sensorineural/cirugía , Tomografía Computarizada por Rayos X/métodos , Dexametasona/uso terapéutico
17.
Laryngoscope ; 134(2): 945-953, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37493203

RESUMEN

OBJECTIVES: Current surgical techniques aim to preserve intracochlear structures during cochlear implant (CI) insertion to maintain residual cochlear function. The optimal technique to minimize damage, however, is still under debate. The aim of this study is to histologically compare insertional trauma and intracochlear tissue formation in humans with a CI implanted via different insertion techniques. METHODS: One recent temporal bone from a donor who underwent implantation of a full-length CI (576°) via round window (RW) insertion was compared with nine cases implanted via cochleostomy (CO) or extended round window (ERW) approach. Insertional trauma was assessed on H&E-stained histological sections. 3D reconstructions were generated and virtually re-sectioned to measure intracochlear volumes of fibrosis and neo-ossification. RESULTS: The RW insertion case showed electrode translocation via the spiral ligament. 2/9 CO/ERW cases showed no insertional trauma. The total volume of the cochlea occupied by fibro-osseous tissue was 10.8% in the RW case compared with a mean of 30.6% (range 8.7%-44.8%, N = 9) in the CO/ERW cases. The difference in tissue formation in the basal 5 mm of scala tympani, however, was even more pronounced when the RW case (12.3%) was compared with the cases with a CO/ERW approach (mean of 93.8%, range 81% to 100%, N = 9). CONCLUSIONS: Full-length CI insertions via the RW can be minimally traumatic at the cochlear base without inducing extensive fibro-osseous tissue formation locally. The current study further supports the hypothesis that drilling of the cochleostomy with damage to the endosteum incites a local tissue reaction. LEVEL OF EVIDENCE: 4: Case-control study Laryngoscope, 134:945-953, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Estudios de Casos y Controles , Cóclea/cirugía , Ventana Redonda/cirugía , Hueso Temporal/cirugía , Electrodos Implantados
18.
Am J Otolaryngol ; 45(1): 104050, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37741025

RESUMEN

BACKGROUND: Cochlear implantation (CI) in children with malformed ears can be challenging through the standard surgical technique. Several alternative approaches have been described. The endoscopic-assisted approach can be chosen as an effective and safe surgical technique, overcoming the drawbacks of the traditional approach. MATERIAL: We further describe a combined technique based on a limited mastoidectomy with no posterior tympanotomy and an endoscopic transmeatal approach to the round window (RW): the electrode is driven from the mastoid to the middle ear through the attic. RESULTS: The concomitant endoscopic assistance allows for improved surgical vision, reducing the risk of major complications. The main advantages of this technique are related to better visualization of the RW for safe insertion of the electrode; avoidance of damage to the facial nerve (FN), due to direct visualization, and sparing the posterior tympanotomy; avoidance of subtotal petrosectomy, if not necessary. CONCLUSION: The purpose of this article, supported with a video file, is to describe step by step this endoscopic-assisted procedure in a patient with middle ear malformation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Niño , Humanos , Implantación Coclear/métodos , Oído/cirugía , Oído Medio/cirugía , Audición , Ventana Redonda/cirugía
19.
Audiol Neurootol ; : 1-12, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38086340

RESUMEN

INTRODUCTION: The primary objective of this article was to determine if any histological alterations occur in the round window (RW) and adjacent anatomical structures of an animal model with normal hearing when a cochlear implant (CI) electrode array is inserted. Furthermore, this article aims to relate these histological alterations to the auditory changes generated. METHODS: Cochlear implantation was performed, following the principles of minimally traumatic surgery (MTS), in 15 ears of nonhuman primates (Macaca fascicularis) (Mf) with normal hearing. Auditory brainstem-evoked potentials (ABR) using clicks and tones were used prior to surgery and during a 6-month follow-up period. Histological evaluation was carried out, analyzing the position of the electrode array with respect to the round window membrane (RWM), its percentage of occupation and integrity, the presence of intracochlear damage, and the tissue reaction provoked, the latter of which was quantified in the temporal bones. RESULTS: Surgery was performed on all 15 ears without relevant incidences. Regarding histology, the electrode array in the RW of all ears presented a lateral position with respect to the modiolus. No lesions affecting the integrity of the RW were observed. The mean value of the array's occupation in the RW was 25%. Tissue reaction, in the form of fibrosis, was observed in all ears and more intensely in the trans-RWM and post-RWM areas. In all ears, the electrodes remained on the scala tympani. No profound hearing impairment was recorded in any ear, being the mean loss of 25.4 dB when comparing presurgical thresholds with those collected 6 months after implantation in ABR click and 24.4 dB in ABR tone burst. CONCLUSIONS: The animal model and Hybrid L-14 (HL14) electrode array were optimal for implementing a surgical technique similar to that routinely performed on humans. Mild histological alterations were observed in the round window membrane and adjacent anatomical structures from the insertion of a cochlear implant electrode array. Following the minimally invasive technique, levels of hearing preservation were satisfactory, reaching a pre-post difference of 25.4 dB in the ABR click and 24.4 dB for a high-frequency tone burst. Complete hearing impairment was not observed in either ear. Correlation between the severity of histological alterations and hearing changes recorded in the ABR studies was observed.

20.
Artículo en Inglés | MEDLINE | ID: mdl-38152919

RESUMEN

BACKGROUND: The primary objective of this study was to analyze middle ear structures critical for cochlear implantation using computed tomography. MATERIALS AND METHODS: Patients who underwent cochlear implantation at the Department of Otolaryngology in Szczecin between 2015 and 2022 were eligible for the study. We analyzed computed tomography images of 57 ears in 52 patients. The following parameters were assessed: mastoid aeration, tegmen tympani height, sigmoid sinus position, posterior tympanotomy width, the distance between the facial nerve and chorda tympani, modified facial recess distance, and the prediction line described by other authors. RESULTS: In 69% of patients, after the removal of the round window bony overhang, the round window membrane became fully visible. There were no statistically significant correlations found for parameters describing mastoid process anatomy or those rating the width of the posterior tympanotomy concerning round window access. The prediction lines, according to Kashio and Jwair, were found to be relevant. In cases where patients' access to the niche and membrane of the window was rated as good or very good during clinical evaluation, they were more likely to describe the window as being located posteriorly or medially in the radiological evaluation. Using a binary Jwair scale provided a better correlation with the clinical assessment. In cases where the windows were graded as posterior, the clinical assessment indicated better surgical access, especially to the RWM (Round Window Membrane). CONCLUSIONS: Evaluating middle ear anatomy on a computed tomography scan is useful for preparing for middle ear surgery but does not significantly affect the ability to access the round window. For such access, the position of the window in relation to the facial nerve is the most relevant factor, and measurements based on this relationship hold the highest clinical value.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...